Australasian Dentist Issue 89
Category 86 AustrAlAsiAn Dentist –Outstanding primary stability with a revolutionary 1-2 step drilling protocol 1 the temporary crown was replaced by a zirconia single implant crown. u Special thanks to Kristjan Lank from Dentalab Estonia for the planning, guide and temporary crown and to Eric van der Winden, dental technician at the Oral Design Center Blaricum the Netherlands for the ceramic crown. tight around the crown. On the x-ray the turnover of the synthetic bone particles is visible. Discussion Although a quite severe subluxation and bone loss has befallen a young patient, the treatment itself was quite minimally invasive and the treatment time was short. the outcome of the treatment was maximally predictable due to the CBCt and intra-oral scanning, which could be combined in a planning software. As a result, the full treatment could be executed in one surgery. After which only MegaGen). Due to the correct implant position, the crown is screw retained with the opening of the screw channel on the palatal side. Before the crown is fitted, the inside of the implant is flushed out with a mouthwash containing active oxygen and a similar gel product is delivered inside of the implant (Blue M). the abutment screw is tightened on 35ncm torque and the screw channel is closed with telfontape and flowable composite. One year postoperative the patient is happy with the result and has no complaints. the soft tissue retracted 0.5 mm, but is still esthetically acceptable. the soft tissue is Irfan Abas is an implant surgeon and prosthodontist (board certified) from the Netherlands. Besides his private practice in Bussum, he is a well-known author of 15 publications, lecturer and is the owner of the Abas Implant Academy. lInICal Figure 15 Blue M gel in the implant Figure 18 Intra oral directly after delivery crown Figure 16 The ceramic screwretained implant crown Figure 19 One year post operative Figure 17 Smile of the patient at fit of the crown Figure 20 X-ray one year post operative s ince the establishment of Dentium in Korea in June 2000, we have been manufacturing high quality dental implant products. in collaboration with leading clinicians, research institutes and universities, the Dentium r&D centre has developed a series of state of the art dental implant systems, focusing on efficiency. Our systems, including fixtures, surgical components, prosthetic Dentium – for dentists by dentists are continuously seeking ways to enhance our product line and services in order to assist the dental professional in providing their patients with a beautiful and healthy smile. We would appreciate your ongoing feedback, as this will assist us in providing you with the highest level of service in the future. u components, and synthetic bone grafting materials, assist our customers in performing quick, accurate and aesthetic dental implantation. As evidence of our quest for providing the highest quality products, Dentium have attained isO13485 and Ce certification. We have also met the manufacturing standards (GMP) set forth by many countries worldwide, including the united states FDA Our ultimate event, the Annual Dentium symposium and the Annual Clinical Case Presentation have been attended by many dental professionals from around the world and serve as the benchmark for educational events. in addition to our ever popular line of implant products, we have entered into the world of bone grafting and regeneration. the bio materials line is proof that we
Made with FlippingBook
RkJQdWJsaXNoZXIy NTgyNjk=